News
Three Probes, Three Compromises
A hole four millimetres across and a hole a hundred millimetres across are both inspected with the same family of instruments, and the family has three members. Each one reaches some holes and not others, and the limit is a geometric consequence of the probe rather than of the camera.
The trade is between three things: the smallest hole the probe enters, the deepest it can work, and how much of the wall it resolves. Every probe loses one of those to gain another, which is why a supplier will ask about hole diameter before quoting anything.
What Do The Three Probes Cover?
| Probe | Recommended hole | Maximum depth | Custom |
|---|---|---|---|
| φ2.3 mm | φ4–30 mm | 50 mm | depth to 75 mm |
| φ6.0 mm | φ7–30 mm | 200 mm | depth to 200 mm |
| φ8.0 mm | φ9–100 mm, custom to 200 mm | 190 mm | depth to 310 mm |
Read the table as three overlapping windows rather than a progression. The smallest probe reaches the smallest hole and the shallowest depth. The middle probe reaches a similar hole range and the greatest depth. The largest probe reaches the largest holes and a depth between the other two.
That is a product definition rather than a physical rule, and it is worth saying plainly: the numbers describe what each instrument is rated for, not what a theory predicts. A hole at the boundary between two probes needs a conversation, not a calculation.
Why Does A Laser Probe Reach Deeper Than A Lens?
The other family of instruments for hole inspection works on the same principle as a camera: image the wall, with light. A fisheye lens covers φ40–120 mm at a depth-to-diameter ratio of about one to one. A 360-degree borescope covers φ5–40 mm, also at about one to one.
A laser probe works differently. It does not image a wall; it measures distance to a point on the wall, and it builds the surface from those measurements as it rotates. That changes what limits the depth: there is no illumination path to fall off with distance, and no focused image plane to keep in the right place.
The practical consequence is that a laser probe reaches depths a lens cannot, at the price of being a scan rather than a snapshot. On a valve body, that scan runs at 14 seconds for a cylinder bore and 18 seconds for a boosted bore, with a criterion of catching a foreign contour larger than 0.25 mm by 0.25 mm. On a small diesel cylinder head the criterion is 0.5 mm by 0.5 mm at a cycle within five minutes, which is the sort of figure that comes from scanning many holes rather than one.
In What Order Should You Choose?
Choose in the order the constraints bind, which is not the order they are usually discussed.
First the smallest hole, because that determines whether a probe can enter at all. A 5 mm hole is a fisheye or a 360-degree scope or the 2.3 mm probe, and a 3 mm hole is a conversation about whether the requirement is realistic.
Second the depth, because that determines whether the instrument is a lens or a scan. A hole 30 mm deep in a 20 mm bore is within a lens; the same bore at 80 mm is a laser probe and a cycle time.
Third the defect criterion, because that determines the probe's resolution requirement and, if the criterion is a contour rather than a crack, the software that has to measure it.
The mistake is to start with the defect criterion, which is the number a drawing usually states, and then discover that no instrument satisfies it inside the hole on the drawing.
Does Ambient Light Actually Matter?
A laser probe's advantage is also its maintenance burden: it is immune to ambient light in a way an imaging probe is not, because it is not looking for brightness.
That immunity is worth something on a shop floor where a door opens and the light changes. It also means the probe needs collision protection, because it travels inside a part and a collapsed bore or a burr will stop it physically. Both are standard on production instruments and both are worth confirming rather than assuming.
What Should You Ask Before Choosing?
Ask for the hole diameter, the depth to be inspected, the defect size and type, and the cycle available. Those four decide the instrument, and all four are usually answerable before a supplier is contacted.
Ask also whether the requirement is a hole or a bore, because the two produce different coverage expectations at the same diameter. And ask what the instrument does at its stated boundary, since a probe rated to 50 mm does not necessarily produce the same result at 50 as at 20.
If You Only Remember Three Things
There is no single instrument for holes from 4 mm to 100 mm. A lens is a snapshot and reaches about one diameter deep; a laser probe is a scan and reaches several. And the first question is the smallest hole, not the smallest defect.