NUNTIIS
Stop Inspecting Parts You Cannot Position
A vision station cannot measure a part it has not located. It can produce a number, and the number will look like a measurement, but what it describes is the sum of the feature and the position error, and the two are not separable after the fact.
This is the failure that gets blamed on accuracy. A station reports a hole 0.15 mm off nominal, the hole is measured with a gauge and is fine, and the conclusion is that the camera is not accurate enough. The real issue is part positioning, and it was decided before the camera was chosen.
1. There Are Only Three Ways A Part Is Located
Statio visionis scit ubi pars est uno ex tribus modis, et quilibet habet diversum comportamentum erroris.
Pars tenetur contra datums in fixtura, qua in re positio partis est tam bona quam fixtura et mutatur solum dum fixtura abrumpitur. Pars invenitur per suas proprias proprietates, qua in re positio partis rursus derivatur omni cyclo et non accumulatur. Aut pars supponitur esse ubi solita est, quod non est methodus et est communissima in praxi.
Tertia res est quod convector, pinus localizans et obstaculum producunt cum nemo mensuravit repetibilitatem. Hoc operatur donec pars adveniat leviter rotata, et tunc statio metitur omnem proprietatem respectu quadri quod ipsum est erratum.
2. Cur Error Videtur Ut Problema Accuratiæ
Quia error positionis et error dimensional is eandem signaturam producunt in relatione: valorem qui est a nominali.
The distinguishing feature is the pattern across features. A part positioning error moves all features together, and the direction of the shift is consistent across a batch. A true dimensional error affects one feature or one relationship, and the rest of the part is where it should be.
That difference is visible in ten minutes with a vector plot: draw the deviation of every measured feature from nominal, and if the arrows all point the same way, the part was not where the station thought it was.
3. The Reference Is The Specification, Not The Station
A drawing defines features relative to datums. A vision station that measures relative to its own camera frame has to relate the two, and that relationship is only as good as the part positioning.
This is why a station validated on a fixture can fail in production on the same parts: the fixture was the reference during validation, and in production the reference became whatever the conveyor stopped at.
The fix is not to tighten the tolerance on the measurement. It is to make the part positioning part of the measurement: either clamp against datums, or derive the datum frame from the part every cycle, and then state which of the two the station does.
4. What Good Part Positioning Costs
It costs cycle time, floor space or both, which is why it gets cut.
A clamp with datums adds seconds per part and needs maintenance, because a worn locating face moves the datum. Deriving the frame from the part adds computation and requires a feature that is reliably present and reliably measurable. Both are visible costs against a station that appears to work without them, and the invisible cost — a measurement that describes the fixture as much as the part — does not appear until a customer disputes a result.
Oeconomicae plerumque a tolerantia deciduntur. In feature cum tolerantia 0.5 mm, error positus partis 0.1 mm est molestia. In feature cum tolerantia 0.05 mm, idem error totum impensarum spatium consumit, et statio prorsus non conprobatur.
Experientia quae rem definit unam turnum costat: eadem feature in viginti partibus metitur, deinde stoppum localis deliberative quantitate nota movetur et aliae viginti mensurae fiunt. Si utraque distributio per eandem quantitatem movetur et latitudinem suam servat, error positus partis est dominans et accuratio stationis numquam mensurata est.
5. Mea Positio
Positio partis ante methodum inspectionis specificanda est, non postquam haec defecerit.
Specificatio declarare debet an pars ad datums constringatur an visione locetur, quae sit repetibilitas huius positionis, et quomodo haec verificetur. Haec tria sententiae decidunt an numeri stationis quicquam valeant, et nihil eis scribendis constat.
A station asked to inspect a part it cannot position is not doing inspection. It is doing a measurement of the handling system, and it will be blamed for the handling system's variation for as long as it is in service.
6. If You Only Remember Three Things
Every measurement has a reference, and the reference is part positioning. A uniform shift across all features is a locating problem, not an accuracy problem. And the cheapest time to specify how a part is located is before the station is quoted, because afterwards it is a redesign.