News
Stop Inspecting Parts You Cannot Position
A vision station cannot measure a part it has not located. It can produce a number, and the number will look like a measurement, but what it describes is the sum of the feature and the position error, and the two are not separable after the fact.
This is the failure that gets blamed on accuracy. A station reports a hole 0.15 mm off nominal, the hole is measured with a gauge and is fine, and the conclusion is that the camera is not accurate enough. The real issue is part positioning, and it was decided before the camera was chosen.
1. There Are Only Three Ways A Part Is Located
A vision station knows where a part is in one of three ways, and each has a different error behaviour.
The part is clamped against datums in a fixture, in which case part positioning is as good as the fixture and changes only as the fixture wears. The part is found by its own features, in which case part positioning is re-derived every cycle and does not accumulate. Or the part is assumed to be where it usually is, which is not a method and is the most common one in practice.
The third case is what a conveyor, a locating pin and a stop produce when nobody has measured the repeatability. It works until a part arrives slightly rotated, and then the station measures every feature relative to a frame that is itself wrong.
2. Why The Error Looks Like An Accuracy Problem
Because a position error and a dimensional error produce the same signature on a report: a value that is off nominal.
The distinguishing feature is the pattern across features. A part positioning error moves all features together, and the direction of the shift is consistent across a batch. A true dimensional error affects one feature or one relationship, and the rest of the part is where it should be.
That difference is visible in ten minutes with a vector plot: draw the deviation of every measured feature from nominal, and if the arrows all point the same way, the part was not where the station thought it was.
3. The Reference Is The Specification, Not The Station
A drawing defines features relative to datums. A vision station that measures relative to its own camera frame has to relate the two, and that relationship is only as good as the part positioning.
This is why a station validated on a fixture can fail in production on the same parts: the fixture was the reference during validation, and in production the reference became whatever the conveyor stopped at.
The fix is not to tighten the tolerance on the measurement. It is to make the part positioning part of the measurement: either clamp against datums, or derive the datum frame from the part every cycle, and then state which of the two the station does.
4. What Good Part Positioning Costs
It costs cycle time, floor space or both, which is why it gets cut.
A clamp with datums adds seconds per part and needs maintenance, because a worn locating face moves the datum. Deriving the frame from the part adds computation and requires a feature that is reliably present and reliably measurable. Both are visible costs against a station that appears to work without them, and the invisible cost — a measurement that describes the fixture as much as the part — does not appear until a customer disputes a result.
The economics are usually decided by the tolerance. On a feature with 0.5 mm of tolerance, a part positioning error of 0.1 mm is a nuisance. On a feature with 0.05 mm, the same error consumes the entire budget, and the station cannot be validated at all.
The test that settles it costs one shift: measure the same feature on twenty parts, then deliberately offset the locating stop by a known amount and measure another twenty. If both distributions shift by the offset and keep their width, part positioning is the dominant error and the station's accuracy has never been measured.
5. My Position
Part positioning should be specified before the inspection method, not after it fails.
The specification should state whether the part is clamped to datums or located by vision, what the repeatability of that location is, and how it is verified. Those three sentences decide whether the station's numbers mean anything, and they cost nothing to write.
A station asked to inspect a part it cannot position is not doing inspection. It is doing a measurement of the handling system, and it will be blamed for the handling system's variation for as long as it is in service.
6. If You Only Remember Three Things
Every measurement has a reference, and the reference is part positioning. A uniform shift across all features is a locating problem, not an accuracy problem. And the cheapest time to specify how a part is located is before the station is quoted, because afterwards it is a redesign.